PCB & PCBA Frequently Asked Questions

PCB & PCBA Frequently Asked Questions

A centralized engineering knowledge base addressing common questions across PCB manufacturing, PCBA assembly, materials, processes, and reliability-driven design decisions.

PCB Manufacturing FAQ

What tests are performed before shipment?

Standard shipment includes 100% electrical continuity testing, with impedance verification provided for controlled-impedance requirements.

Why is the finished thickness 0.65 mm instead of 0.508 mm in some designs?

Using a standard RO4350B core plus copper and solder mask thickness can result in 0.65 mm finished thickness; this improves manufacturability and material consistency with negligible RF impact.

Why use resin-filled (resin-plugged) vias on a 2-layer RF board?

Resin filling prevents solder wicking, improves surface planarity for SMT, and reduces solder defects—especially helpful for fine-pitch assembly.

What impedance tolerance can you support on this 2-layer RO4350B PCB?

Target-dependent control within ±10% is supported, with impedance verification available for controlled-impedance structures.

What is Rogers RO4350B and why is it used for RF PCBs?

RO4350B is a low-loss high-frequency laminate with stable dielectric properties, helping reduce RF loss and improve impedance predictability compared with standard FR-4.

What is the difference between PCB and PCBA testing?

PCB testing focuses on verifying the bare board’s structural and electrical integrity—checking traces, vias, and layer alignment before components are added. PCBA testing validates the fully assembled board’s performance, confirming that every component functions correctly under real-world operating conditions.

When should impedance testing be performed?

Impedance testing should be carried out during the PCB fabrication stage—before assembly—to confirm that all controlled impedance traces meet design specifications. It’s essential for RF, microwave, and high-speed digital circuits.

What’s the benefit of flying probe testing compared to in-circuit testing (ICT)?

Flying probe testing is fixtureless and ideal for prototypes or small batches, offering flexibility with lower setup costs. ICT, on the other hand, is faster and more suitable for mass production, providing detailed diagnostics for every net and component.

How does functional testing (FCT) ensure product reliability?

FCT simulates real operating conditions—powering up the board, loading firmware, and testing I/O interfaces—to confirm that the final assembly performs exactly as intended. It’s the last step before product shipment to ensure zero functional defects.

What types of reliability tests are available for system-level assemblies?

We perform a full range of reliability tests including burn-in, thermal cycling, vibration, and humidity testing. These simulate long-term use and harsh environments to guarantee durability and stability over the product’s life cycle.

How do you handle testing for high-density or complex boards (e.g., BGA or HDI PCBs)?

We use a combination of X-ray inspection (AXI) and boundary-scan (JTAG) to analyze hidden solder joints and interconnects. This allows non-intrusive diagnostics of fine-pitch components and multi-layer connections without physical probing.

Can testing data be included in the final quality documentation?

Yes. We provide detailed test reports, measurement records, and visual inspection data upon request. These documents are fully traceable and can be used for customer quality audits or regulatory compliance verification.