Step Drill / Controlled Depth Drilling

Step Drill / Controlled Depth Drilling

Multiple-diameter and depth-controlled holes for special mechanical and electrical needs.

Step Drill / Controlled Depth Drilling — Process Capabilities & DFM Guide

Controlled-depth drilling shapes the z-axis of your interconnects: stable press-fit seats, precise countersinks, thermal counterbores, and selective backdrill to minimize stubs—without over-processing the entire panel.

 

 

Process Capability Matrix(Core Specs)

Type

Typical Use

Drill Ø Range (mm)

Step Height / Depth

Depth Tolerance

Registration (XY)

Board Thickness

Notes

Step Drill (Counterbore)

Screw seats, thermal pads

0.80–6.50

≥0.20 mm step

±0.05–0.10 mm

≤±50 µm

≤4.0 mm

Flat bottom seat; copper keep-out needed

Countersink (Chamfer)

Screw/connector heads

1.00–6.50

60°/82°/90°

±2° angle, depth ±0.10

≤±60 µm

≤4.0 mm

Angle per fastener standard

Controlled-Depth Blind Drill

Cavity, pad relief

0.20–0.50

To target dielectric

±0.05–0.08 mm

≤±40 µm

≤3.2 mm

Laser/Mech hybrid by stack-up

Selective Backdrill

Stub reduction

0.20–0.45

Residual stub ≤0.20 mm

±0.05–0.10 mm

≤±50 µm

≤4.0 mm

Per net, one-side program

Multi-Step Hole

Press-fit tuning

1.00–3.20

Dual steps ≥0.20/step

±0.08–0.10 mm

≤±60 µm

≤3.2 mm

Hole wall quality controlled

 

 

 

DFM & Package Rules

  • Copper keep-out: ≥0.25–0.35 mm radial around counterbore/countersink to avoid exposed planes.
  • Annular ring: For stepped pads, maintain ≥0.10–0.15 mm after etch compensation.
  • Stack-up datum: Specify drilling from TOP or BOT; depth referenced to layer index (e.g., stop above L3).
  • Mask strategy: Keep mask clearance around step rim 0.10–0.15 mm to avoid chipping.
  • Press-fit: Match hole class (plated/unplated). For plated press-fit, set finished Ø & insertion force target; consider step seat for head support.
  • Thermal seats: Use counterbore to thin dielectric path; connect to copper pour with spokes if solderability is needed.
  • Backdrill: Define start/stop layers and max residual stub (e.g., ≤0.20 mm critical, ≤0.30 mm non-critical).

 

 

Manufacturing Flow & Controls

Tooling & datum → Pilot drill / peck cycle → Z-depth calibration (contact probe) → Controlled-depth drilling (spindle encoder) → Deburr & wall inspection → PTH / pattern plate (if plated) → Counterbore/countersink verification → Mask/finish → Metrology (CMM, pin gauge, cross-section).

 

 

 

Quality & Verification

Item

Method

Criteria (Typical)

Note

Depth accuracy

Contact gauge / CMM

±0.05–0.10 mm

Per program side

Angle accuracy

Optical protractor

±2°

60°/82°/90° options

Residual stub

Cross-section / X-ray

≤0.20 mm critical nets

Backdrill lots

Wall quality

Endoscope / Cross-section

No delam/burr/cracks

After plating if PTH

Pad concentricity

Vision AOI

≤0.10 mm

For stepped pads

 

 

 

Typical Applications

  • Press-fit connectors: stepped seats for head support; controlled interference in plated holes.
  • Screw & standoff seats: counterbore/countersink for mechanical clearance.
  • Thermal counterbores: shorten dielectric path to copper heatsink.
  • Selective backdrill: minimize stubs on high-speed through vias near BGAs or connectors.
  • RF shielding: countersunk holes for shield can frames to sit flush.
     

 

Common Issues → Countermeasures

  • Exposed plane → Increase copper keep-out; re-reference depth to stop above target layer.
  • Burrs / fiber pull-out → Optimize peck cycle and tool; apply post-drill deburr; verify wall before PTH.
  • Depth overshoot → Re-calibrate Z; reduce feed near target; use pilot pocketing.
  • Stub too long → Tighten backdrill stop; verify start layer; add fiducial witness.

Get Custom Quote

PRODUCTS CENTER

Supported formats: PDF, DWG, Gerber, Excel (Max 50MB)
Submit