PCB & PCBA Frequently Asked Questions
A centralized engineering knowledge base addressing common questions across PCB manufacturing, PCBA assembly, materials, processes, and reliability-driven design decisions.
FAQ
PRODUCTS CENTER
Get Custom Quote
PRODUCTS CENTER
Copper PCB FAQ
How to solve the CTE mismatch between the copper foil and the substrate in thick copper PCBs?
Use buffer layer materials (such as thermal conductive adhesive films) or design stress relief slots.
What are the requirements for the abrasion resistance of the solder resist ink in thick copper PCBs?
After 500 rubbings (500g pressure), there is no obvious wear or copper exposure.
How to correct the hole position deviation of drilled holes in thick copper PCBs?
Mark point positioning is used, and the deviation is detected and compensated by an AOI device.
What is the detection method for the hardness of the electroplated copper layer in thick copper PCBs?
A micro-Vickers hardness tester is used, with the distance between test points ≥0.5mm, and the average value is taken.
How to optimize the layer stack structure of multi-layer boards in the design of thick copper PCBs?
The power layer and the ground layer are adjacent, the signal layers are sandwiched in the middle, and the uniformity of the medium thickness is controlled.
What are the process parameters for solder resist ink printing on thick copper PCBs?
Screen tension 25-35N/cm, squeegee pressure 3-5kg/cm, speed 30-50mm/s.
How to repair oxidized copper foil in thick copper PCBs?
Slight oxidation can be treated with chemical micro-etching, and severe oxidation requires re-surface treatment.
What are the methods to suppress signal reflection in thick copper PCBs?
Match terminal impedance, optimize trace topology, and reduce right-angle traces and impedance discontinuities.
What are the requirements for the edge milling accuracy of thick copper PCBs?
Outline dimension tolerance ±0.1mm, angle deviation ±0.5°.
What is the detection method for the uniformity of the electroplated copper layer in thick copper PCBs?
An X-ray fluorescence spectrometer (XRF) is used to measure the thickness of the copper layer at different positions, with a deviation ≤10%.
How to calculate the current-carrying capacity of vias in the design of thick copper PCBs?
A single 0.5mm via can carry about 0.5-1A, and the number of vias needs to be determined according to the actual current demand.
What is the measurement method for the surface roughness of copper foil in thick copper PCBs?
A surface profiler is used to measure the Ra value, and the Ra of conventional copper foil is ≤5μm.
Get Custom Quote