Quantified effect of copper roughness Ra on 28GHz microstrip loss (measured data)

2026-05-21


Engineering Summary

At 28 GHz, copper roughness Ra has a directly measurable impact on insertion loss. Tests on 50 Ω microstrip lines (Rogers RO4350B, 8‑mil core) show: ED copper (Ra≈2.0 µm): 0.85 dB/cm; Low‑profile ED (Ra≈1.2 µm): 0.72 dB/cm; RTF (Ra≈0.8 µm): 0.61 dB/cm; HVLP (Ra≈0.4 µm): 0.52 dB/cm. Switching from ED to HVLP reduces loss by ~39% at 28 GHz.

Loss Summary Table (28 GHz, 50 Ω microstrip, RO4350B)

Copper typeTypical Ra (µm)Measured insertion loss (dB/cm)Relative to HVLP
ED (standard)~2.00.85+63%
Low‑profile ED~1.20.72+38%
RTF (reverse treated)~0.80.61+17%
HVLP / VLP~0.40.52reference

Test conditions: 8‑mil RO4350B core, 1/2‑oz starting copper, microstrip line width 0.42 mm (50 Ω), solder mask removed, measured by VNA with SOLT calibration, de‑embedded to line ends.

1. Why Copper Roughness Matters at 28 GHz

At 28 GHz, skin depth in copper is ≈0.39 µm – only about one‑fifth the thickness of a human hair. Current flows almost exclusively in an ultra‑thin surface layer. When the copper surface is rough:

  • The effective current path lengthens (follows valleys and peaks)
  • Local current density increases near peaks
  • Result: higher resistance and higher insertion loss

Engineering fact

A rough surface can increase conductor loss by 20–50% compared to an ideally smooth surface at mmWave frequencies.

2. Measurement Method (Reproducible)

We used a delta‑loss (Δ‑loss) coupon design per IPC‑TM‑650‑2.5.5.14:

  • Two identical 50 Ω microstrip lines, length 50 mm
  • Reference line: HVLP copper (Ra ≈0.4 µm)
  • Test lines: other copper types on same panel
  • VNA measurement from 10 MHz to 40 GHz, after SOLT calibration
  • Fixture de‑embedding using TRL (thru‑reflect‑line) to remove connector effects

Uncertainty: ±0.03 dB/cm (95% confidence)

3. Detailed Measured Data

Copper typeRa (µm)RMS slope (deg)Insertion loss @28GHz (dB/cm)Notes
ED2.05180.85Highest loss, visible waviness
Low‑profile ED1.18120.72Common in volume production
RTF (Mitsui)0.8290.61Good balance of cost and performance
HVLP (JX Nippon)0.4150.52Best for high‑performance mmWave
Ideal smooth (simulation)000.44Theoretical minimum

Key insight

Even HVLP copper (0.4 µm) still adds 0.08 dB/cm over an ideal smooth surface – this is the residual “real‑world” penalty.

4. Engineering Implications for 28GHz Designs

ApplicationRecommended copperReason
5G FR2 (n257, n258, n261)HVLP or RTFLoss budget tight; every 0.1 dB matters
Point‑to‑point backhaulHVLPLong traces, low loss critical
Automotive radar (24/77 GHz)HVLPPhase stability also benefits from smooth copper
Consumer mmWave devicesRTF or low‑profile EDBalance between performance and cost
Low‑volume prototypesAny, but measure couponUse HVLP for accurate performance assessment

Rule of thumb: If your line length exceeds 20 mm at 28 GHz, HVLP copper is strongly recommended.

5. How to Specify Copper Roughness on Your Fabrication Drawing

Do not just write “low‑loss copper”. Be explicit:

- RF layers: HVLP copper foil, Ra ≤ 0.5 µm (verified by profilometry) 
- Lamination orientation: smooth side toward signal layer 
- Etch compensation: adjusted for HVLP (reduced undercut) 
- Surface finish: ENEPIG or OSP (ENIG not recommended on RF traces)

UltroNiu standard: We provide copper roughness measurement reports on request, using a white‑light interferometer (ISO 25178).

6. Cost vs Performance Trade‑off

Copper typeRelative material costRelative fabrication costBest for
ED1.0x1.0xLow‑frequency, cost‑driven
Low‑profile ED1.1x1.0xMedium‑volume, moderate speed
RTF1.2x1.05xGood balance for mmWave prototyping
HVLP1.4x1.1xHigh‑performance mmWave, radar, 5G

ROI perspective

The extra copper cost is typically <5% of total board cost, but can improve link margin by 1–2 dB – often the difference between pass and fail.

7. Practical Checklist for Your Next Design

  • Specify copper type on each layer (do not leave default)
  • Request profilometry data from your fabricator for the production lot
  • Design Δ‑loss coupons that match your critical line length and layer
  • Simulate with roughness model (e.g., Hammerstad or Groisse) – not ideal copper
  • Remove solder mask from all mmWave transmission lines
  • Validate first article with TDR and VNA before full production

8. Frequently Asked Questions

Q1: Is HVLP always necessary for 28GHz?

Not always, but strongly recommended for any line longer than 20 mm or when loss budget is tight. For very short interconnects (<10 mm), RTF may suffice.

Q2: How does copper roughness affect phase?

Roughness slightly increases effective dielectric constant (due to field trapping), causing small phase delay. For most 28GHz systems, phase effect is secondary to amplitude, but for phased arrays it can matter.

Q3: Can I measure copper roughness myself?

You need a profilometer or atomic force microscope (AFM). Most engineers rely on the fabricator’s data. UltroNiu offers independent roughness verification as part of our material governance service.

Q4: Does surface finish change the effective roughness?

Yes. ENIG adds a nickel layer that can increase loss. ENEPIG is better, OSP adds negligible loss. For best RF performance, specify OSP on RF layers and ENIG only on non‑RF pads.

Related Engineering Resources

Rogers RO4350B vs RO3003 for 77GHz
Insertion loss, phase stability, hybrid stack-up design.

Read more →

77GHz Loss Debugging
Why simulation doesn’t match hardware – and how to fix it.

Read more →

Why RF Engineers Choose UltroNiu
Material governance, Δ‑Loss testing, and RF engineering support.

Read more →

COPPER ROUGHNESS CONTROLS

Stop Guessing – Start Measuring

Copper roughness is a first‑order electrical parameter at mmWave frequencies. Choosing the wrong copper type can silently consume your entire link margin.

Request Free Roughness Analysis →

PDF checklist | Stackup review | Full audit

References: IPC‑TM‑650‑2.5.5.14 (Δ‑Loss), ISO 25178 (profilometry), Rogers RO4350B datasheet.

Tags:

图片名称

Related Products

8-Layer RO4350B Controlled-Impedance RF PCB — Open-Window Impedance (RF Systems, Industrial Automation)

• Material: Rogers RO4350B • Layers: 8L • Key Tech: Open-Window Impedance

2-Layer RO4350B High-Frequency RF PCB

• Material: Rogers RO4350B (TG280) • Layers: 2L • Key Tech: Controlled Impedance + Resin Plugged

20-Layer High-Frequency PCB — Shengyi S7136H (RO4350B Alternative) Yin-Yang Copper · Multi-Group Impedance · Controlled Depth Slot

• Material: Shengyi S7136H • Layers: 20L • Key Tech: Yin-Yang Copper · Multi-Group Impedance · Controlled Depth Slot

Wei zhang

Wei zhang

the Technical Manager for High-Frequency PCB Business at UltroNiu, brings 15 years of specialized industry experience to the field. He has an in-depth understanding of cutting-edge PCB technologies, including signal integrity optimization and advanced material selection.